Semiconductor Physics, Quantum Electronics & Optoelectronics, 28 (2), P. 158–165 (2025).
DOI: https://doi.org/10.15407/spqeo28.02.158


Thermoluminescent dosimetry of mixed nuclear radiation: Radioisotope stands

O.M. Pop1, V.T. Maslyuk1, N.I. Svatiuk1, A.V. Rusyn2, P.V. Yavorskyi1, V.I. Roman1

1Institute of Electron Physics, Uzhhorod, Ukraine
2Transcarpathian Cancer Center, Uzhhorod, Ukraine
*Corresponding author e-mail: pop.ksenja@gmail.com

Abstract. The study results of dosimeters based on doped lithium fluoride and carbon C-based leucosapphire are presented for use in mixed γ-n fields. The radiation conditions were created using the radioisotope stands based on certified 60Co and Pu–α-Be sources. It is shown that the studied dosimeters are promising for recording the absorbed dose starting from 1 mGy for γ- and mixed γ-n radiation factors. The sensitivity of TLD-100H (LiF:Mg,Cu,P) dosimeters was determined to be several times higher than that of TLD-100 (LiF:Mg,Ti) and Al2O3:C. A sensitivity parameter was introduced to quantify the efficiency of dosimetric materials for fixed irradiation conditions. The dependence of luminous intensity on the dose or irradiation time for γ- and mixed γ-n irradiation is shown.

Keywords: radiation stands, ?-n radiation, dosimeters, lithium fluoride, leucosapphire.

Full Text (PDF)

Back to Volume 28 N2

Creative Commons License
This work is licensed under a Creative Commons Attribution-NoDerivatives 4.0 International License.